Key Features
-
12V 9Ah capacity for dependable runtime on gate automation systems
-
F2 / 6.3mm faston terminals—drop-in replacement in most cabinets
-
Sealed, non-spillable AGM/SLA design (maintenance-free)
-
Standby life 3–5 years (typical, environment dependent)
-
High surge handling: up to 135A (5s) for peak loads
-
ActivFire listed (afp3824); conforms to IEC 60896-21:2004 & IEC 60896-22:2004
Recommended Uses
-
Backup power for G-Force 12V gate motors & control boards
-
Alarm/IoT modules on gates (GSM, Wi-Fi, keypads, photo-eyes)
-
Small 12V UPS/backup applications around the gate enclosure
Specifications
-
Nominal Voltage: 12V (6 cells)
-
Capacity (20-hr to 10.5V): 9Ah
-
Internal Resistance: ~18 mΩ
-
Max Discharge Current: 135A (5s)
-
Max Charge Current: 2.52A
-
Charge Voltage (cyclic): 14.4–15.0V
-
Float Voltage (standby): 13.5–13.8V
-
Terminal Type: F2 / 6.3mm spade
-
Container Material: ABS
-
Dimensions (L×W×H): 151 × 65 × 100 mm (incl. tabs)
-
Weight: ~2.65 kg
Operating Temperature
-
Charge: 0°C to 40°C
-
Discharge: −15°C to 50°C
-
Storage: −15°C to 40°C
Compliance & Handling
-
UN Number: UN 2800 (Non-Spillable, Hazard Class 8)
-
ActivFire Listed: afp3824
-
Standards: IEC 60896-21:2004, IEC 60896-22:2004
Installation Notes (G-Force Tips)
-
Mount upright where possible with good ventilation; avoid enclosed hot spaces.
-
Do not install in engine bays. ABS cases can be affected by temps >65°C.
-
Use correct float voltage (13.5–13.8V) for longest life; avoid chronic under/over-charge.
-
Periodically test load/voltage—replace if capacity noticeably drops.
Specs may change without notice. Always verify fitment and charging parameters with your control board manual.